This schematic diagram of iPhone 5 will be a great tool for phone technicians.
Click this link to download the manual >>
https://drive.google.com/open?id=0B5AGZAAwnkQZVEF4WVk5dEc2VGc
Samsung Front Load Washer Troubleshooting Guide
This course will describe the features, service modes, testing and troubleshooting changes of the new large capacity front load washer.
Click this link to download the manual >>
https://drive.google.com/open?id=0B5AGZAAwnkQZUnlocHBOei1sXzQ
Click this link to download the manual >>
https://drive.google.com/open?id=0B5AGZAAwnkQZUnlocHBOei1sXzQ
Samsung Refrigerator Advanced Troubleshooting Guide
This training is provided to assist the student in servicing Samsung refrigerators. The training covers common failure mode, diagnostic procedures and efficient troubleshooting. This course is not written for a specific model rather it covers the variety of Samsung refrigeration products.
Click this link to download >>
https://drive.google.com/open?id=0B5AGZAAwnkQZTWp6ZERUS3JXcDA
https://drive.google.com/open?id=0B5AGZAAwnkQZTWp6ZERUS3JXcDA
Fault Analysis and Troubleshooting for Air Conditioner
1. The principle of troubleshooting
From indoor to outdoor, side parts to central components, fan motor to compressor. Please listen to and ask the user carefully about the fault and information related, then make a judgment based on your experience and check the units regarding the fault description. Please do not remove any part blindly or the fault might be expanded.
2. Preparations for troubleshooting
1) Please check whether the power supply has voltage and whether the voltage is in accordance with the operation requirements of A/C (single phase: 198V-242V; three phases: 342V-418V);
2) Please check whether the power wire, the indoor and outdoor connecting line is correct and reliable;
3) Please check whether the wire insulation is damaged.
3. Troubleshooting
Window Type
| Failure | Probable reasons | Probable reasons | Probable reasons | Solutions |
| whole unit is out of work | no power supply | | | wait for the power supply |
| leakage switch trips | switch fault | | replace the leakage switch | |
| winding insulation of fan motor is cracked | | replace the fan motor | ||
| winding insulation of compressor is cracked | | replace the compressor | ||
| compressor is blocked | rotor is cracked | replace the compressor | ||
| winding of transformer is open circuit | | | replace the transformer | |
| fuse on the PCB is open circuit | | | replace the fuse | |
| PCB fault | 7805 component fault | | replace the 7805 component or PCB | |
| No cooling effect | setting of the remote controller is improper | | | set the remote controller properly |
| fan motor is out of work | PCB has no output | relay is out of work | replace the relay or PCB | |
| chip is out of work | replace the chip or PCB | |||
| capacitor decays completely | | replace the capacitor | ||
| bearing of the fan motor is blocked deadly | | replace the fan motor | ||
| winding of fan motor is open circuit | | replace the fan motor | ||
| compressor is out of work | PCB has no output | relay is out of work | replace the relay or PCB | |
| chip is out of work | replace the chip or PCB | |||
| capacitor decays | | replace the capacitor | ||
| winding of compressor is open circuit | | replace the compressor | ||
| compressor is blocked | rotor is cracked | replace the compressor | ||
| compressor is not sucking or discharging | rotor is cracked | replace the compressor | ||
| no refrigerant | leakage | | find the leakage points and fill refrigerant after repairing welding. | |
| poor cooling | The setting temp of the remote controller is too high. | | | Turn down the setting temp. |
| room is not sealed enough | | | seal the room | |
| filter is too dirty | | | clean the filter | |
| evaporator or condenser is too dirty | | | clean the evaporator or condenser | |
| revolving speed of fan motor is slow | capacitor decays | | replace the capacitor | |
| winding resistance of fan motor is less than normal | | replace the fan motor | ||
| refrigerant is not enough | leakage | | find the leakage points and fill refrigerant after repairing welding | |
| poor air exhaustion | it’s blocked with sundries | | clean the sundries | |
| Noisy | fan blade vibrates | fan blade is cracked | | replace the fan blade |
| bearing of fan motor is wearing | | | replace the fan motor | |
| water leakage | water plate is filth blockage | | | clean up the dirty stuff |
| evaporator is too dirty | | | clean the evaporator | |
| evaporator frost | refrigerant is not enough | | find the leakage points and fill refrigerant after repairing welding | |
| revolving speed of fan motor is too slow | capacitor decays | replace the capacitor | ||
| winding resistance of fan motor is less than normal | replace the fan motor | |||
| Cannot remote controlling | strong light resource exists nearby | | | replace the A/C or adjust position of the light resource |
| remote controller fault | remote controller is locked | | open the remote controller | |
| no battery or the battery lacks of power | | put the battery in or replace the battery | ||
| remote controller damaged | | replace the remote controller | ||
| receiver doesn’t receive signal | | | replace the receiver or PCB |
Digital Television in the Philippines
Online Channels
Metro Manila (Mega Manila)
Frequency: 647.143MHz
ABS-CBN
ABS-CBN Sports+Action
CINEMO! ------------------- (Encrypted) Only available on TVplus
YEY! ----------------------- (Encrypted) Only available on TVplus
Knowledge Channels ------ (Encrypted) Only available on TVplus
DZMM Teleradyo ---------- (Encrypted) Only available on TVplus
ABS-CBN 1seg (for mobile 1seg built-in tuners)
Frequency: 641.143MHz (New Frequency)
PTV SD1
PTV SD2
PTV SD3
PTV 1seg (for mobile 1seg built-in tuners)
Frequency: 695.143MHz
TV5
AKSYON TV
CATSUP (Test Broadcast)
TV5 1SEG (for mobile 1seg built-in tuners)
Frequency: 551.143MHz
GMA
GMA News TV
GMA 1SEG (for mobile 1seg built-in tuners)
Frequency: 521.143MHz
ETC
Jack City
2nd Avenue
HSN (Blink TV \"SM Cinema\")
Frequency: 581.143MHz
BEAM 1 Seg (for mobile 1seg built-in tuners)
BEAM TV
O Shopping
TV Shop
TBN Asia
Frequency: 617.143MHz
UNTV-1
UNTV-2
ADDTV
UNTV 1seg (for mobile 1seg built-in tuners)
Frequency: 653.143
Hope Phil HD
3ABN
Hope Inter SD
Frequency: 683.143MHz (Online Test Broadcast 12:00AM to 4:00AM Only)
INCTV HD
NET25 HD
INCTV SD
NET25 SD
INCTV-1Seg (for mobile 1seg built-in tuners)
NET25-1Seg (for mobile 1seg built-in tuners)
Provincial Areas
ABS-CBN - Central Luzon Frequency: 533.143MHz
ABS-CBN - Calabarzon Frequency: 677.143MHz
ABS-CBN - Cebu City Frequency: 611.143MHz
Offline Channels
Reserved Frequency: 677.143MHz
SMNI Frequency: 629.143MHz
RPN (CNN Philippines) Frequency 503.143
TVplus Manual Scan Video: <click here for link>
This post is from TipidPC.com thread, for more updates and information, please visit this link and join the forum.
Metro Manila (Mega Manila)
Frequency: 647.143MHz
ABS-CBN
ABS-CBN Sports+Action
CINEMO! ------------------- (Encrypted) Only available on TVplus
YEY! ----------------------- (Encrypted) Only available on TVplus
Knowledge Channels ------ (Encrypted) Only available on TVplus
DZMM Teleradyo ---------- (Encrypted) Only available on TVplus
ABS-CBN 1seg (for mobile 1seg built-in tuners)
Frequency: 641.143MHz (New Frequency)
PTV SD1
PTV SD2
PTV SD3
PTV 1seg (for mobile 1seg built-in tuners)
Frequency: 695.143MHz
TV5
AKSYON TV
CATSUP (Test Broadcast)
TV5 1SEG (for mobile 1seg built-in tuners)
Frequency: 551.143MHz
GMA
GMA News TV
GMA 1SEG (for mobile 1seg built-in tuners)
Frequency: 521.143MHz
ETC
Jack City
2nd Avenue
HSN (Blink TV \"SM Cinema\")
Frequency: 581.143MHz
BEAM 1 Seg (for mobile 1seg built-in tuners)
BEAM TV
O Shopping
TV Shop
TBN Asia
Frequency: 617.143MHz
UNTV-1
UNTV-2
ADDTV
UNTV 1seg (for mobile 1seg built-in tuners)
Frequency: 653.143
Hope Phil HD
3ABN
Hope Inter SD
Frequency: 683.143MHz (Online Test Broadcast 12:00AM to 4:00AM Only)
INCTV HD
NET25 HD
INCTV SD
NET25 SD
INCTV-1Seg (for mobile 1seg built-in tuners)
NET25-1Seg (for mobile 1seg built-in tuners)
Provincial Areas
ABS-CBN - Central Luzon Frequency: 533.143MHz
ABS-CBN - Calabarzon Frequency: 677.143MHz
ABS-CBN - Cebu City Frequency: 611.143MHz
Offline Channels
Reserved Frequency: 677.143MHz
SMNI Frequency: 629.143MHz
RPN (CNN Philippines) Frequency 503.143
TVplus Manual Scan Video: <click here for link>
This post is from TipidPC.com thread, for more updates and information, please visit this link and join the forum.
AUO 39inch T390XVN01.0 Open Cell Data Sheet
This specification applies to the 38.5 inch Color TFT-LCD SKD model T390XVN01.0. This Open Cell Unit has a TFT active matrix type liquid crystal panel 1,366x768 pixels, and diagonal size of 38.5 inch. This Open Cell Unit supports 1,366x768 mode. Each pixel is divided into Red, Green and Blue sub-pixels or dots which are arranged in vertical stripes. Gray scale or the brightness of the sub-pixel color is determined with a 8-bit gray scale signal for each dot.
Please contact the blogger if you need the PDF format of this datasheet.
Please contact the blogger if you need the PDF format of this datasheet.
LED TV with USB Multimedia Playback Supported Format (MStar v59 Chipset
Most LED TV's now has USB Port to play different media format such as movie, music and photos.
But don't be surprised if you downloaded some files and when you play it in your TV, it won't run or there is a message that its not supported. Below are the list of files and format which mstar v59 supports.
Subscribe to:
Posts (Atom)
-
This specification applies to the 38.5 inch Color TFT-LCD SKD model T390XVN01.0. This Open Cell Unit has a TFT active matrix type liquid cry...
-
This specification applies to the 65 inch Color TFT-LCD Module T645HW02 V3. This LCD module has a TFT active matrix type liquid crystal pane...
-
1. The principle of troubleshooting From indoor to outdoor, side parts to central components, fan motor to compressor. Please listen to and ...













